Rua
Manufacturer
Locally manufactured
Fan fed TLUD designed for rice husk. They are very popular and are sold in large numbers without subsidy. Works great as an automatic rice cooker with 3 cups husk for 1 cup rice. A fan delivers a small amount of air to the bottom of a biomass cylinder and a large amount of oxygen at the top of the cylinder. This heating of the biomass in a low oxygen environment results in the production of charcoal (biochar) and a large amount of smoke. This smoke is then burnt in the plate of fire which occurs when the gas released from the heated biomass meets the additional oxygen supplied at the top of the stove.
IWA tiers of performance
Information for consumers
Maximum pot capacity
not available
Approximate lifetime
3 years
People fed per meal
1-6
Pot type accommodated
(Flat bottom/Round bottom)
(Flat bottom/Round bottom)
Flat bottom
Countries deployed
Viet Nam
Common foods cooked
Asian meals that cook in under 40 minutes
Manufacturer's warranty available?
No
General information
Manufactured in
Viet Nam
Suggested retail price
USD 16-20
Availability
On the market
Dimensions (l/w/h)
300/300/450 mm
Weight
3.0 kg
Shipping dimensions
300/330/450 mm
Shipping weight
3.0 kg
Local assembly possible?
Yes
Materials needed for local assembly
Stainless steel cutting and wielding capabilities
Includes instructions?
No
Other information
not available
Characteristics
Non-traditional, Portable, Batch loaded, Biochar-producing, Gasifier (TLUD), Heating, Household, Fan
Fuels
Charcoal, Crop residues, Pellets, Wood
Materials
Metal
Performance details
IWA emissions
Metric | Min value | Max value | Number of tests |
---|---|---|---|
IWA high power CO | 9.27 g/MJ-del | 9.27 g/MJ-del | 1 |
IWA efficiency
Metric | Min value | Max value | Number of tests |
---|---|---|---|
IWA high power thermal efficiency | 17.6 % | 17.6 % | 1 |
Efficiency, energy consumption and fuel use
Metric | Min value | Max value | Number of tests |
---|---|---|---|
Specific energy consumption | 3700.0 kJ/task | 3700.0 kJ/task | 1 |
Fuel consumed | 1265.0 g/task | 1265.0 g/task | 1 |
Burning rate cold start | 29.88 g/min | 29.88 g/min | 1 |
Output
Metric | Min value | Max value | Number of tests |
---|---|---|---|
Mean time to boil | 23.0 min | 23.0 min | 1 |