SCODE SP-FL micro gasifier portable
SCODE SP-FL micro gasifier portable

This is a gasifier stove driven by a low power fan that burns any kind of biomass smokelessly and efficiently. It has the advantage of being a front loading stove.

IWA tiers of performance
Show subtiers
unrated
Emissions
1
Efficiency
unrated
Indoor emissions
unrated
Safety
Information for consumers
Maximum pot capacity
40 L
Approximate lifetime
5 years
People fed per meal
1-80
Pot type accommodated
(Flat bottom/Round bottom)
Both
Countries deployed
Kenya
Common foods cooked
Those to be boiled and fried
Manufacturer's warranty available?
Yes
Warranty details
1 year
General information
Manufactured in
Kenya
Suggested retail price
USD 50-80
Availability
On the market
Dimensions (l/w/h)
not available
Weight
not available
Shipping dimensions
40/30/45 mm
Shipping weight
not available
Local assembly possible?
Yes
Materials needed for local assembly
Whytheat K refractory cement, gauge 18 MS metal sheets, electric speed fan of up to 32cfm (3watts) and its regulators, Portland cement, vermiculite, and skill
Includes instructions?
No
Other information
External power source is required to power the fan. It can be solar or electricity. But the stove is designed to work even when the fan is turned off, though not as well.
Characteristics
Batch loaded, Gasifier (TLUD), Household, Portable, Side-feed, Fan, Non-traditional
Fuels
Charcoal, Crop residues, Wood
Materials
Cement, Ceramic, Metal
Performance details
IWA efficiency  
Metric Min value Max value Number of tests
IWA high power thermal efficiency 30.366 % 30.366 % 1
IWA low power specific consumption 0.0513 MJ/min/L 0.0513 MJ/min/L 1
Efficiency, energy consumption and fuel use
Metric Min value Max value Number of tests
Simmer thermal efficiency 31.09 % 31.09 % 1
Specific fuel consumption cold start 85.19 g/L 85.19 g/L 1
Specific fuel consumption hot start 149.65 g/L 149.65 g/L 1
Temp-corrected specific consumption cold start 90.48 g/L 90.48 g/L 1
Temp-corrected specific consumption hot start 155.05 g/L 155.05 g/L 1
Temp-corrected specific energy cons cold start 1666.0 kJ/L 1666.0 kJ/L 1
Temp-corrected specific energy cons hot start 2855.0 kJ/L 2855.0 kJ/L 1
Burning rate hot start 34.36 g/min 34.36 g/min 1
Burning rate cold start 10.26 g/min 10.26 g/min 1
Burning rate simmer 5.99 g/min 5.99 g/min 1
Output
Metric Min value Max value Number of tests
Cold start firepower 3150.0 W 3150.0 W 1
Hot start firepower 10544.0 W 10544.0 W 1
Simmer firepower 1837.0 W 1837.0 W 1
Time to boil cold start 23.0 min 23.0 min 1
Time to boil hot start 11.67 min 11.67 min 1
Temp-corrected time to boil cold start 23.88 min 23.88 min 1
Temp-corrected time to boil hot start 12.21 min 12.21 min 1
Turn down ratio 3.57 3.57 1