Side Feed Fan Stove
Manufacturer
Website
The stove features fast jets of air that enter the combustion chamber below the burning wood and charcoal. The fast jets of air create superior mixing of air and wood gas and result in clean combustion. The fan also increases the velocity of the overall exhaust gasses resulting in higher thermal efficiency.
IWA tiers of performance
Information for consumers
Maximum pot capacity
10 L
Approximate lifetime
3 years
People fed per meal
5-15
Pot type accommodated
(Flat bottom/Round bottom)
(Flat bottom/Round bottom)
Flat bottom
Countries deployed
not available
Common foods cooked
Any food that can be cooked in a pot at low or high power.
Manufacturer's warranty available?
No
General information
Manufactured in
China
Suggested retail price
USD 20
Availability
Prototype
Dimensions (l/w/h)
480/260/350 mm
Weight
6.6 kg
Shipping dimensions
360/360/480 mm
Shipping weight
7.6 kg
Local assembly possible?
No
Includes instructions?
No
Other information
not available
Characteristics
Non-traditional, Household, Portable, Side-feed, Ceramic-lined, Fan, Prototype
Fuels
Wood
Materials
Ceramic, Metal
Performance details
IWA emissions
Metric | Min value | Max value | Number of tests |
---|---|---|---|
IWA high power CO | 1.76 g/MJ-del | 1.76 g/MJ-del | 1 |
IWA high power PM | 47.198 mg/MJ-del | 47.198 mg/MJ-del | 1 |
IWA low power CO | 0.012 g/min/L | 0.012 g/min/L | 1 |
IWA low power PM | 0.47 mg/min/L | 0.47 mg/min/L | 1 |
IWA efficiency
Metric | Min value | Max value | Number of tests |
---|---|---|---|
IWA high power thermal efficiency | 47.11 % | 47.11 % | 1 |
IWA low power specific consumption | 0.01 MJ/min/L | 0.01 MJ/min/L | 1 |
IWA indoor emissions
Metric | Min value | Max value | Number of tests |
---|---|---|---|
IWA CO | 0.159 g/min | 0.159 g/min | 1 |
IWA PM | 4.463 mg/min | 4.463 mg/min | 1 |
Efficiency, energy consumption and fuel use
Metric | Min value | Max value | Number of tests |
---|---|---|---|
Cold start thermal efficiency | 46.76 % | 46.76 % | 1 |
Hot start thermal efficiency | 49.61 % | 49.61 % | 1 |
Simmer thermal efficiency | 41.5 % | 41.5 % | 1 |
Specific fuel consumption cold start | 47.89 g/L | 47.89 g/L | 1 |
Specific fuel consumption hot start | 45.33 g/L | 45.33 g/L | 1 |
Temp-corrected specific consumption cold start | 42.91 g/L | 42.91 g/L | 1 |
Temp-corrected specific consumption hot start | 41.92 g/L | 41.92 g/L | 1 |
Temp-corrected specific energy cons cold start | 828.79 kJ/L | 828.79 kJ/L | 1 |
Temp-corrected specific energy cons hot start | 809.63 kJ/L | 809.63 kJ/L | 1 |
Burning rate hot start | 9.85 g/min | 9.85 g/min | 1 |
Burning rate cold start | 10.35 g/min | 10.35 g/min | 1 |
Burning rate simmer | 4.267 g/min | 4.267 g/min | 1 |
Output
Metric | Min value | Max value | Number of tests |
---|---|---|---|
Cold start firepower | 3333.0 W | 3333.0 W | 1 |
Hot start firepower | 3171.0 W | 3171.0 W | 1 |
Simmer firepower | 1374.0 W | 1374.0 W | 1 |
Time to boil cold start | 41.14 min | 41.14 min | 1 |
Time to boil hot start | 40.0 min | 40.0 min | 1 |
Temp-corrected time to boil cold start | 36.91 min | 36.91 min | 1 |
Temp-corrected time to boil hot start | 36.99 min | 36.99 min | 1 |
Turn down ratio | 2.61 | 2.61 | 1 |