SuperSaver Wood GL (M-5000)
SuperSaver Wood GL (M-5000)

Wood stove designed for localized mass production.

IWA tiers of performance
Show subtiers
1
Emissions
2
Efficiency
1
Indoor emissions
3
Safety
Information for consumers
Maximum pot capacity
not available
Approximate lifetime
not available
People fed per meal
not available
Pot type accommodated
(Flat bottom/Round bottom)
not available
Countries deployed
Australia, Bolivia, Burundi, Cambodia, Cameroon, Canada, China, Congo, Côte d'Ivoire, Democratic Republic of Congo, Ethiopia, Fiji, Finland, France, Germany, Ghana, Guatemala, Haiti, Honduras, Hungary, India, Indonesia, Ireland, Kenya, Liberia, Madagascar, Malawi, Mali, Mexico, Mozambique, Namibia, Nepal, Netherlands, Nicaragua, Nigeria, Papua New Guinea, Peru, Philippines, Poland, Portugal, Rwanda, Senegal, Singapore, South Africa, Spain, Switzerland, Tonga, Uganda, United Kingdom, United Republic of Tanzania, United States, Viet Nam, Zambia, Zimbabwe
Common foods cooked
not available
Manufacturer's warranty available?
No
General information
Manufactured in
Kenya
Suggested retail price
not available
Availability
On the market
Dimensions (l/w/h)
320/320/280 mm
Weight
4.2 kg
Shipping dimensions
335/335/292 mm
Shipping weight
5.34 kg
Local assembly possible?
No
Includes instructions?
No
Other information
not available
Characteristics
Rocket, Portable, Household, Non-traditional
Fuels
Wood
Materials
Metal
Performance details
IWA emissions  
Metric Min value Max value Number of tests
IWA high power CO 2.26 g/MJ-del 4.1 g/MJ-del 3
IWA high power PM 429.2 mg/MJ-del 690.2 mg/MJ-del 2
IWA low power CO 0.04 g/min/L 0.053 g/min/L 2
IWA low power PM 0.726 mg/min/L 2.99 mg/min/L 2
IWA efficiency  
Metric Min value Max value Number of tests
IWA high power thermal efficiency 29.7 % 38.8 % 3
IWA low power specific consumption 0.025 MJ/min/L 0.032 MJ/min/L 2
IWA indoor emissions  
Metric Min value Max value Number of tests
IWA high power indoor CO 0.15 g/min 0.301 g/min 3
IWA low power indoor CO 0.22 g/min 0.22 g/min 1
IWA high power indoor PM 19.4 mg/min 50.7 mg/min 2
IWA low power indoor PM 7.3 mg/min 7.3 mg/min 1
Efficiency, energy consumption and fuel use
Metric Min value Max value Number of tests
Average thermal efficiency 29.7 % 29.7 % 1
Emissions
Metric Min value Max value Number of tests
Average CO emissions 15.7 g 15.7 g 1
Average PM emissions 1127.0 mg 1127.0 mg 1
EPTP metrics
Metric Min value Max value Number of tests
Average fuel use 655.0 g 655.0 g 1