This stove is pending approval by the Catalog team and not publicly visible in the Catalog. You may edit the stove until it has been approved.

Ganesha 3 Stove
Ganesha 3 Stove
Manufacturer
PureFlame

Batch-fed, natural draft gasifier

IWA tiers of performance
Show subtiers
2
Emissions
1
Efficiency
1
Indoor emissions
unrated
Safety
Information for consumers
Maximum pot capacity
not available
Approximate lifetime
not available
People fed per meal
not available
Pot type accommodated
(Flat bottom/Round bottom)
Flat bottom
Countries deployed
Nepal
Common foods cooked
not available
Manufacturer's warranty available?
No
General information
Manufactured in
Nepal
Suggested retail price
USD 12
Availability
On the market
Dimensions (l/w/h)
190/190/330 mm
Weight
1.8 kg
Shipping dimensions
387/315/77 mm
Shipping weight
2.5 kg
Local assembly possible?
Yes
Materials needed for local assembly
not available
Includes instructions?
Yes
Instruction details
not available
Other information
not available
Characteristics
Non-traditional, Household, Portable, Side-feed, Rocket
Fuels
Crop residues, Dung, Pellets, Wood
Materials
Metal
Performance details
IWA emissions  
Metric Min value Max value Number of tests
IWA high power CO 7.7 g/MJ-del 7.7 g/MJ-del 1
IWA high power PM 328.1 mg/MJ-del 328.1 mg/MJ-del 1
IWA low power CO 0.08 g/min/L 0.08 g/min/L 1
IWA low power PM 3.86 mg/min/L 3.86 mg/min/L 1
IWA efficiency  
Metric Min value Max value Number of tests
IWA high power thermal efficiency 35.4 % 35.4 % 1
IWA low power specific consumption 0.041 MJ/min/L 0.041 MJ/min/L 1
IWA indoor emissions  
Metric Min value Max value Number of tests
IWA high power indoor CO 0.52 g/min 0.52 g/min 1
IWA high power indoor PM 21.5 mg/min 21.5 mg/min 1
Efficiency, energy consumption and fuel use
Metric Min value Max value Number of tests
Temp-corrected specific consumption cold start 76.0 g/L 76.0 g/L 1
Temp-corrected specific energy cons cold start 1398.0 kJ/L 1398.0 kJ/L 1
Output
Metric Min value Max value Number of tests
Cold start firepower 2750.0 W 2750.0 W 1
Time to boil cold start 33.5 min 33.5 min 1
EPTP metrics
Metric Min value Max value Number of tests
Average fuel use 847.0 g 847.0 g 1