Kenya Uhai
Kenya Uhai
Manufacturer
Locally manufactured

Disseminated by Practical Action in reported quantities of approximately 1,000 per year. Cooking pot rests directly on the ceramic liner, rather than on metal pot rests. Ceramic liner has a lip that reduces the size of the opening on top.

IWA tiers of performance
Show subtiers
0
Emissions
2
Efficiency
0
Indoor emissions
unrated
Safety
Information for consumers
Maximum pot capacity
not available
Approximate lifetime
not available
People fed per meal
not available
Pot type accommodated
(Flat bottom/Round bottom)
not available
Countries deployed
Kenya
Common foods cooked
not available
Manufacturer's warranty available?
No
General information
Manufactured in
Kenya
Suggested retail price
not available
Availability
On the market
Dimensions (l/w/h)
not available
Weight
not available
Shipping dimensions
not available
Shipping weight
not available
Local assembly possible?
No
Includes instructions?
No
Other information
not available
Characteristics
Non-traditional, Household, Portable, Ceramic-lined
Fuels
Charcoal
Materials
Metal, Ceramic
Performance details
IWA emissions  
Metric Min value Max value Number of tests
IWA high power CO 18.25 g/MJ-del 24.75 g/MJ-del 2
IWA high power PM 308.5 mg/MJ-del 319.5 mg/MJ-del 2
IWA low power CO 0.092 g/min/L 0.094 g/min/L 2
IWA low power PM 0.242 mg/min/L 0.58 mg/min/L 2
IWA efficiency  
Metric Min value Max value Number of tests
IWA high power thermal efficiency 29.1 % 30.1 % 2
IWA low power specific consumption 0.016 MJ/min/L 0.018 MJ/min/L 2
IWA indoor emissions  
Metric Min value Max value Number of tests
IWA CO 0.89 g/min 1.162 g/min 2
IWA PM 11.022 mg/min 12.2 mg/min 2
Efficiency, energy consumption and fuel use
Metric Min value Max value Number of tests
Cold start thermal efficiency 25.6 % 27.1 % 2
Hot start thermal efficiency 32.5 % 33.1 % 2
Fuel consumed 67.0 g/task 69.0 g/task 2
Output
Metric Min value Max value Number of tests
Cold start firepower 3332.0 W 3334.0 W 2
Hot start firepower 4556.0 W 5073.0 W 2
Simmer firepower 1144.0 W 1246.0 W 2
Mean time to boil 28.3 min 31.1 min 2
Emissions
Metric Min value Max value Number of tests
PM2.5 emissions factor (2) 1.48 g/kg fuel 1.84 g/kg fuel 2
CO emissions factor (2) 170.425 g/kg fuel 194.325 g/kg fuel 2
CH4 emissions factor (2) 4.2654 g/kg fuel 7.29625 g/kg fuel 2
PM2.5 emissions rate 8.567248645 mg/min 9.948393951 mg/min 2
CO emissions rate 0.89 g/min 1.162 g/min 2