Test result
Water boiling test (WBT)
Stove and fuel
Stove description
Honey(s)-metal-v
Stove characteristics
Chimney, Non-traditional
Fuel type
Coal
Fuel description
Honeycomb Coal Briquette from a special coal mine in Shanxi
Fuel moisture content
0.03%
Fuel net calorific value
20.3 MJ/kg
Test information
Test details
MWBT-VITA
Testing organization
Rutgers University
Reporting type
Not available
Country
China
Year performed
2000
Test environment
Lab
Altitude
not available
Number of replicate tests
3
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
unrated
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
IWA emissions  
Metric Value SD (σ) Cv
IWA high power CO 13.529 g/MJ-del
IWA high power PM 142.87 mg/MJ-del
Emissions
Metric Value SD (σ) Cv
CO emissions factor (2) 58.9 g/kg fuel