Test result
Controlled cooking test (CCT)
Stove and fuel
Stove description
Open fire
Stove characteristics
Other open fire
Fuel type
Wood
Fuel description
Fire Wood
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
CCT, Cook dough into tortillas (1350g)
Testing organization
The Micronutrient Initiative
Reporting type
Not available
Country
Guatemala
Year performed
2000
Test environment
Field
Altitude
2200 m
Number of replicate tests
20
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
unrated
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
Efficiency, energy consumption and fuel use
Metric Value SD (σ) Cv
Fuel consumed 970.0 g/task 510.0 0.53
Output
Metric Value SD (σ) Cv
Mean time to boil 17.1 min
CCT/UCT metrics
Metric Value SD (σ) Cv
Specific consumption (fuel) 719.0 g fuel/kg food 378.0 0.53
Specific consumption (energy) 13.3 MJ/kg food 7.0 0.53
Time to cook food 17.1 min 11.7 0.68