Stove and fuel
Stove description
8-wick non-pressurized kerosene stove.
Stove characteristics
Wick, Non-traditional
Fuel type
Kerosene
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
WBT-3.0, 5 Liters Boiled
Testing organization
Reporting type
Not available
Country
United States
Year performed
2010
Test environment
Lab
Altitude
not available
Number of replicate tests
3
Source information
Source data
not available
Test result IWA tiers of performance
Performance metrics
IWA emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power CO | 1.63 g/MJ-del | ||
IWA high power PM | 0.979 mg/MJ-del | ||
IWA low power CO | 0.016 g/min/L | ||
IWA low power PM | 0.031 mg/min/L |
IWA efficiency
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power thermal efficiency | 51.597443% | ||
IWA low power specific consumption | 0.02 MJ/min/L |
IWA indoor emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA CO | 0.097 g/min | ||
IWA PM | 0.093 mg/min |
Efficiency, energy consumption and fuel use
Metric | Value | SD (σ) | Cv |
---|---|---|---|
Specific energy consumption | 9700.0 kJ/task | ||
Fuel consumed | 223.0 g/task | ||
Hot start thermal efficiency | 51.3% | ||
Cold start thermal efficiency | 51.9% |
Output
Metric | Value | SD (σ) | Cv |
---|---|---|---|
Cold start firepower | 1977.0 W | ||
Hot start firepower | 1859.0 W | ||
Simmer firepower | 1799.0 W | ||
Mean time to boil | 41.9 min |
Emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
CO emissions factor (2) | 46.24106675 g/kg fuel | ||
CO emissions rate | 0.097227149 g/min |