Stove and fuel
Stove description
A single-burner mass-produced camping stove fueled by a small 1-pound propane cylinder.
Stove characteristics
Non-traditional
Fuel type
Liquefied Petroleum Gas (LPG)
Fuel description
LPG
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
WBT-3.0, 5 Liters Boiled
Testing organization
Reporting type
Not available
Country
United States
Year performed
2010
Test environment
Lab
Altitude
not available
Number of replicate tests
3
Source information
Source data
not available
Test result IWA tiers of performance
Performance metrics
IWA emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power CO | 0.473 g/MJ-del | ||
IWA high power PM | 1.225 mg/MJ-del | ||
IWA low power CO | 0.0 g/min/L | ||
IWA low power PM | 0.014 mg/min/L |
IWA efficiency
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power thermal efficiency | 67.6621675% | ||
IWA low power specific consumption | 0.013 MJ/min/L |
IWA indoor emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA CO | 0.013 g/min | ||
IWA PM | 0.059 mg/min |
Efficiency, energy consumption and fuel use
Metric | Value | SD (σ) | Cv |
---|---|---|---|
Specific energy consumption | 6700.0 kJ/task | ||
Fuel consumed | 140.0 g/task | ||
Hot start thermal efficiency | 66.1% | ||
Cold start thermal efficiency | 69.2% |
Output
Metric | Value | SD (σ) | Cv |
---|---|---|---|
Cold start firepower | 1946.0 W | ||
Hot start firepower | 1915.0 W | ||
Simmer firepower | 1072.0 W | ||
Mean time to boil | 23.0 min |
Emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
CO emissions factor (2) | 8.617890483 g/kg fuel | ||
CO emissions rate | 0.012661756 g/min |