Test result: SaverPro 100 (Envirofit EFI-100L)
Emissions and Performance Test Protocol (EPTP)
Stove and fuel
Stove characteristics
Non-traditional, Rocket, Portable, Chimney, Institutional
Fuel type
Wood
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
not available
Reporting type
Third party
Country
United States
Year performed
2014
Test environment
Lab
Altitude
1525 m
Number of replicate tests
not available
Source information
Citation
not available
Source data
not available
Test result IWA tiers of performance
Show subtiers
1
Emissions
4
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
IWA emissions  
Metric Value SD (σ) Cv
IWA high power CO 2.0 g/MJ-del
IWA high power PM 496.2 mg/MJ-del
IWA low power CO 0.01 g/min/L
IWA low power PM 0.464 mg/min/L
IWA efficiency  
Metric Value SD (σ) Cv
IWA high power thermal efficiency 45.7%
IWA low power specific consumption 0.003 MJ/min/L