Test result: Rua
Water boiling test (WBT)
Stove and fuel
Stove
Stove characteristics
Non-traditional, Portable, Batch loaded, Biochar-producing, Gasifier (TLUD), Heating, Household, Fan
Fuel type
Crop residues
Fuel description
Rice husk
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
The test began at time 945 seconds and ended at time 3485 seconds. Water was boiling at time 2296 seconds. The boiling point was 99.5 degrees centigrade. During the test, the stove consumed 1265 grams fuel and produced 420 grams charcoal.
Reporting type
Third party
Country
China
Year performed
2013
Test environment
Lab
Altitude
not available
Number of replicate tests
1
Source information
Citation
not available
Source data
not available
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
unrated
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
IWA emissions  
Metric Value SD (σ) Cv
IWA high power CO 9.27 g/MJ-del
Efficiency, energy consumption and fuel use
Metric Value SD (σ) Cv
Fuel consumed 1265.0 g/task
Burning rate cold start 29.88 g/min
Specific energy consumption 3700.0 kJ/task
Output
Metric Value SD (σ) Cv
Mean time to boil 23.0 min