Test result: LPG Stove Télia n°2
Water boiling test (WBT)
Stove and fuel
Stove characteristics
Non-traditional, Household, Portable, Batch loaded, Pot skirt
Fuel type
Liquefied Petroleum Gas (LPG)
Fuel moisture content
not available
Fuel net calorific value
44.7 MJ/kg
Test information
Test details
WBT 4.2.3
Reporting type
Third party
Country
Burkina Faso
Year performed
2014
Test environment
Lab
Altitude
not available
Number of replicate tests
6
Source information
Citation
not available
Source data
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
3
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
IWA efficiency  
Metric Value SD (σ) Cv
IWA high power thermal efficiency 49.247241%
IWA low power specific consumption 0.01742445 MJ/min/L
Efficiency, energy consumption and fuel use
Metric Value SD (σ) Cv
Simmer thermal efficiency 61.628% 4.753 0.08
Specific fuel consumption cold start 15.709 g/L 0.932 0.06
Specific fuel consumption hot start 15.564 g/L 1.3001 0.08
Temp-corrected specific consumption cold start 17.332 g/L 1.134 0.07
Temp-corrected specific consumption hot start 17.203 g/L 1.348 0.08
Temp-corrected specific energy cons cold start 774.747 kJ/L 50.697 0.07
Temp-corrected specific energy cons hot start 768.96 kJ/L 60.263 0.08
Burning rate cold start 7.508 g/min 0.557 0.07
Burning rate hot start 7.358 g/min 0.947 0.13
Burning rate simmer 2.185 g/min 0.181 0.08
Output
Metric Value SD (σ) Cv
Cold start firepower 5593.41 W 415.19 0.07
Hot start firepower 5481.81 W 705.8 0.13
Simmer firepower 1627.96 W 135.18 0.08
Time to boil cold start 14.33 min 0.52 0.04
Time to boil hot start 14.5 min 1.38 0.1
Temp-corrected time to boil cold start 15.808 min 0.512 0.03
Temp-corrected time to boil hot start 16.033 min 1.54 0.1
Turn down ratio 3.458 0.416 0.12