Test result: SCODE SP-FL micro gasifier Concrete body
Water boiling test (WBT)
Stove and fuel
Stove characteristics
Non-traditional, Household, Institutional, Built in place, Portable, Side-feed, Heating, Ceramic-lined, Fan
Fuel type
Wood
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
not available
Reporting type
Self reported
Country
Kenya
Year performed
2014
Test environment
Lab
Altitude
not available
Number of replicate tests
3
Source information
Citation
not available
Source data
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
0
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
IWA efficiency  
Metric Value SD (σ) Cv
IWA high power thermal efficiency 30.37%
IWA low power specific consumption 0.05 MJ/min/L
Efficiency, energy consumption and fuel use
Metric Value SD (σ) Cv
Simmer thermal efficiency 31.1%
Specific fuel consumption cold start 85.0 g/L
Specific fuel consumption hot start 150.0 g/L
Temp-corrected specific consumption cold start 90.0 g/L
Temp-corrected specific consumption hot start 155.0 g/L
Temp-corrected specific energy cons cold start 1666.0 kJ/L
Temp-corrected specific energy cons hot start 2855.0 kJ/L
Burning rate cold start 34.0 g/min
Burning rate hot start 10.0 g/min
Burning rate simmer 6.0 g/min
Output
Metric Value SD (σ) Cv
Cold start firepower 3150.0 W
Hot start firepower 10544.0 W
Simmer firepower 1837.0 W
Time to boil cold start 23.0 min
Time to boil hot start 11.67 min
Temp-corrected time to boil cold start 24.0 min
Temp-corrected time to boil hot start 12.0 min
Turn down ratio 4.0