Test result: Philips HD4012
Kitchen performance test (KPT)
Stove and fuel
Stove characteristics
Non-traditional, Fan, Gasifier (TLUD), Portable, Household, Ceramic-lined
Fuel type
Wood
Fuel moisture content
9.5%
Fuel net calorific value
not available
Test information
Test details
Emissions testing in households in the Chikhwawa District.
Reporting type
Third party
Country
Malawi
Year performed
2015
Test environment
Field
Altitude
not available
Number of replicate tests
8
Test result IWA tiers of performance
Show subtiers
unrated
Emissions
unrated
Efficiency
unrated
Indoor emissions
unrated
Safety
Performance metrics
Efficiency, energy consumption and fuel use
Metric Value SD (σ) Cv
Fuel consumed 0.67 g/task 0.58 0.87
Emissions
Metric Value SD (σ) Cv
EC emissions factor (2) 0.8 g/kg fuel 0.3 0.38
EC/TC 0.4 0.1 0.25
CO emissions factor (2) 53.8 g/kg fuel 21.3 0.4
OC emissions factor (2) 0.96 g/kg fuel 0.12 0.13
PM2.5 emissions factor (2) 4.1 g/kg fuel 0.6 0.15
CO emissions rate 0.58 g/min 0.28 0.48
PM2.5 emissions rate 44.8 mg/min 12.3 0.27
CO2 emissions factor (2) 1749.0 g/kg fuel 33.0 0.02
CO2 emissions rate 18.7 g/min 3.8 0.2
EC emissions rate 8.8 mg/min 3.7 0.42
OC emissions rate 10.4 mg/min 2.5 0.24