Stove and fuel
Stove characteristics
Traditional, Household
Fuel type
Charcoal
Fuel moisture content
4.1%
Fuel net calorific value
not available
Test information
Test details
not available
Testing organization
Reporting type
Third party
Country
United States
Year performed
not available
Test environment
Lab
Altitude
not available
Number of replicate tests
3
Source information
Citation
not available
Source data
not available
Test result IWA tiers of performance
Performance metrics
IWA emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power CO | 35.33 g/MJ-del | 1.84 | 0.05 |
IWA high power PM | 442.9 mg/MJ-del | 46.32 | 0.1 |
IWA low power CO | 0.2 g/min/L | 0.01 | 0.05 |
IWA low power PM | 0.322 mg/min/L | 0.13 | 0.4 |
IWA efficiency
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power thermal efficiency | 20.9% | ||
IWA low power specific consumption | 0.0218 MJ/min/L |
IWA indoor emissions
Metric | Value | SD (σ) | Cv |
---|---|---|---|
IWA high power indoor CO | 1.641 g/min | 0.17 | 0.1 |
IWA low power indoor CO | 0.7 g/min | 0.03 | 0.04 |
IWA high power indoor PM | 20.54 mg/min | 2.78 | 0.14 |
IWA low power indoor PM | 1.6 mg/min | 0.2 | 0.13 |
Output
Metric | Value | SD (σ) | Cv |
---|---|---|---|
Temp-corrected time to boil cold start | 34.1 min | ||
Temp-corrected time to boil hot start | 35.4 min |