Test result: THX-T14
Water boiling test (WBT)
Stove and fuel
Stove
Stove characteristics
Household, Portable, Batch loaded, Gasifier (TLUD)
Fuel type
Wood
Fuel moisture content
not available
Fuel net calorific value
not available
Test information
Test details
WBT Version 4.2.3
Testing organization
Renewable Energy and New Materials Institute (REMI)
Reporting type
Third party
Country
Lao People's Democratic Republic
Year performed
2016
Test environment
Lab
Altitude
not available
Number of replicate tests
not available
Source information
Citation
not available
Source data
Test result IWA tiers of performance
Show subtiers
2
Emissions
0
Efficiency
2
Indoor emissions
2
Safety
Performance metrics
IWA emissions  
Metric Value SD (σ) Cv
IWA high power CO 6.0 g/MJ-del 2.78 0.46
IWA high power PM 64.4 mg/MJ-del 47.6 0.74
IWA low power CO 0.1159 g/min/L 0.0155 0.13
IWA low power PM 0.6744 mg/min/L 0.6966 1.03
IWA efficiency  
Metric Value SD (σ) Cv
IWA high power thermal efficiency 26.38% 1.88 0.07
IWA low power specific consumption 0.0536 MJ/min/L 0.004 0.07
IWA indoor emissions  
Metric Value SD (σ) Cv
IWA CO 0.5725 g/min 0.2652 0.46
IWA PM 5.9029 mg/min 4.6576 0.79
IWA safety  
Metric Value SD (σ) Cv
IWA safety 2.0